八 地震作用内力计算
(一)重力荷载代表值计算
1.屋面雪荷载标准值
Qsk=0.65×[7.8×6×(7.2×2+3.0)+3.9×(3.0+7.2)+7.8×7.2×2+10.1×3.9+3.9×7.2]=0.65×1034=787kN
2.楼面活荷载标准值
Q1k=Q2k=2.5×[3.0×7.8×6+3.9×(3.0+7.2)+3.9×(7.2×3+10.1) +3.9×7.2]+2.0×(7.8×7.2×12+3.9×7.2 +7.8×10.1)=2.5×332+2.0×781=2397kN
Q3k=Q4k=2.5×332+2.0×(7.8×7.2×12+3.9×7.2)=2.5×332+2.0×702=2239kN
3.屋盖、楼盖自重
G5k=25×{1034×0.1+0.2×(0.6-0.1)×(7.2×12+3.9×2)+0.3×(0.8-0.1)×